info Richiedi informazioni

Luperini Group, dal 2010, si presenta attraverso una solida struttura, dinamica e articolata, organizzata per interfacciarsi con l’industria farmaceutica e altri importanti settori della produzione industriale.

Made in excellence made in Luperini

I tre brand Luperini Tailored Pharma Machinery , Luperini Qualified Pharma Service e Luperini Qualified Tech Service operano su un terreno condiviso fatto di know how tecnologico, forte spinta innovativa, ricerca della massima qualità del prodotto e del servizio, predisposizione alla customizzazione delle soluzioni.

Group Numbers

10+

Anni di esperienza

3

Aziende

100+

Persone

I brand di Luperini dedicati all’industria farmaceutica capitalizzano la radicata competenza di un team che si distingue per la grande esperienza nel settore.

logo Luperini Tailored Pharma Machinery

Luperini – Tailored Pharma Machinery

Il brand Tailored Pharma Machinery propone tecnologie fortemente personalizzate e caratterizzate da grande affidabilità ed accuratezza.

Scopri di più
logo Luperini Qualified Pharma Service

Luperini Qualified Pharma Service

Luperini Qualified Pharma Service eroga una gamma
di servizi d’eccellenza: riqualificazione e revamping
di impianti attivi, ricambistica e componenti oltre a investimenti del cliente. consulenza e interventi di manutenzione ordinaria e
straordinaria.

Scopri di più

Luperini Qualified Tech Service mette in campo un’articolata attività di service per l’integrazione, la manutenzione e installazione di impianti produttivi rivolti a diversi settori industriali fra cui spicca quello del Tissue.

logo Luperini Qualified Tech Service

Luperini – Qualified Tech Service

Grazie ad una facilitie di 5000 mq, Luperini Qualified Tech Service è in grado di offrire al cliente un servizio altamente qualificato di pre-montaggio impianti ed effettuare collaudi e test per mettere al sicuro gli investimenti del cliente.

Scopri di più

Quantità di soluzione legante necessaria per la granulazione umida nei granulatori High Shear

NEWS_5_IT

Nel capitolo conclusivo di Luperini Science, scritto dalla Professoressa Erica Franceschinis, Professore Associato dell’Università degli Studi di Padova, esploriamo come attraverso l’automazione si possa superare gli approcci tradizionali nei processi di granulazione. Disponibile in inglese, il Capitolo 5 di Luperini Science è una guida pratica per ottimizzare i processi produttivi attraverso l’impiego di specifiche tecnologie abilitanti.

Amount of liquid binder necessary for the HSWG

Liquid bridges represent the main forces involved in the formation of the wet granule structure. When the granulating liquid is added to the formulation, it gradually penetrates the powder bed, filling the voids between the particles that are initially connected to each other by the formation of liquid bridges. The subsequent addition of liquid leads to gradual filling of the voids until a slurry is formed. Depending on the amount of liquid added, the powders experience different capillary saturation states. The saturation states are called pendular, funicular, capillary, and slurry states and are represented in Fig. 1. The optimal amount of liquid binder necessary to perform the wet granulation process in a high shear mixer is that which allows transition from pendular to funicular state.

img1
Figure 1. Graphical representation of the different liquid saturation states experienced by a powder while it is gradually wetted.

The optimal amount of liquid binder is still often evaluated through an empirical assessment defined as hand squeeze test. This assessment consists of squeezing a sample of wet powder into a fist. The amount of liquid is optimal if the squeezed wet mass maintains a compacted shape after the disclosure of the fist and presents some breakages (Fig. 2). This approach is also used as an in-process control for high-shear granulation. This method is not reliable as it is hugely affected by the experience and the sensitivity of the operator.

Figure 2. Hand squeeze test.

To conduct a systematic assessment, it is possible to equip the granulator with potentiometers, ammeters, or torque meters to monitor electrical or mechanical parameters associated with the granulator’s motor or impeller movement during the addition of liquid binder and the evolution of the process. The measured parameters are generally the torque recorded by the impeller of the high-shear mixer or the adsorbed power of the engine.

An example of the shape of torque profile registered during the addition of the liquid binder to the powders inside a high shear granulator is reported in Fig. 3.

Figure 3. Torque profile registered by the impeller of a high shear mixer during the addition of the liquid binder to the powder mixture.

The torque profile can be divided into five sections:

S1 corresponds to the wetting of the powder. In this phase only the initial bridges between the primary particles are formed.

S2 a rapid increase of the torque values is observed; this phase corresponds to the achievement of the pendular saturation state.

S3 corresponds to the transition between the pendular and funicular saturation states. This transition is represented as a plateau of the torque profile.

S4 represents the filling of the pores between the particles and the achievement of the capillary state.

S5 represents the drop phase characterised by a drop in mass resistance.

The identification of the different liquid saturation states of the mass on a high-shear mixer opened the way to the use of the torque recorded during the process to identify when the amount of liquid added is sufficient to perform the granulation, thus avoiding the hand squeeze test.